— Frequently Asked Questions: RSA Hz and RSA Hz PRO —

WARNING

“The motor must be installed by a professional in motorisation and building automation, in accordance with the SIMU instructions
and the regulations applicable in the country of use.”

SIMPLIFIED DOCUMENTATION

HOW TO WIRE A SAFETY EDGE?

HOW TO ACTIVATE A SAFETY EDGE?


Optical safety edge: Setting P1 = 02
Setting P5 = 04
Resistive safety edge: Setting P1 = 02
Setting P5 = 03

HOW TO ADD A SEQUENTIAL REMOTE CONTROL?

1. Go to setting P8, 00 flashes.
2. Press the button on your remote control until 00 stays lit.
3. Without releasing the button on your remote control; press + on the unit until two lines (–) appear.
4. Release, then using the scroll arrows, go to C1 and test your remote control.
5. Repeat the same operation with the other remote controls.
Sequential mode EN 

HOW TO ADD A FUNCTIONAL REMOTE CONTROL?

1. Go to setting P8, 00 flashes.
2. Press the Up button on your remote control until 00 stays lit.
3. Without releasing the button on your remote control; press + on the unit until two lines (–) appear.
4. On setting P8, with the + button, scroll to 01 and program the Down button in the same way as the Open button.
5. On setting P8, with the + button, scroll to 02 and program the Stop button.
6. Using the scroll arrows, go to C1 and test your remote control.
3 buttons mode EN

HOW TO ADD A DIGICODE?

ajouter-un-digicode-EN
Click here to download the manual
—> Digicode

HOW TO CONNECT PHOTOELECTRIC CELLS?

wiring photo-cell EN

Click here to download the manual
—> CELL MASTER PRO BITECH

HOW TO ACTIVATE PHOTOELECTRIC CELLS?


Setting P2 = 02
Setting P6 = 03

HOW TO CONNECT REFLEX CELLS?

brancher cellule reflex

Click here to download the manual
—> REFLEX CELL

HOW TO WIRE a safety brake ?

HOW TO WIRE AN ORANGE SIGNAL LIGHT AND/OR AREA LIGHTING?

Without area lighting: PA 03
With area lighting: PA 04
Wiring of lighting EN
Click here to download the manual
—> SIGNAL LIGHT

HOW TO WIRE A SEQUENTIAL CONTROL POINT?